• Text Size:
  • a
  • a
ainsworth maguire public relations manchester web text logo

b2b public relations since 1985

Home News Rooms PR Quote What is PR? About Us PR Services Online PR Brochures PR Tips PR Blog Contact Links Site Map

You are in: home > news rooms > senior hargreaves > HVAC Ductwork for New Liverpool Hilton

Search Ainsworth Maguire PR Manchester site Search Site...

Return to Index

Back | Next

Senior Hargreaves Logo - HVAC Ductwork

Senior Hargreaves
Lord Street
Bury, Lancashire
BL9 0RG
United Kingdom

T.+44(0)161 764 5082
F.+44(0)161 762 2336

info@
senior-hargreaves.co.uk


www.hargreaves-ductwork.co.uk

Media info e-mail:
pr@ainsmag.co.uk


Add to:

AddThis Senior Hargreaves Social Bookmark Button AddThis Senior Hargreaves News Feed Button

Sustainability and Safety Key Aims of HVAC Ductwork for New Liverpool Hilton

The prestigious 215 bedroom Liverpool Hilton, under construction and due to open in Summer 2009, will be supplied with HVAC ductwork by specialist contractor Senior Hargreaves. Kier Build Limited is the main contractor. Ductwork for air input and extract will ensure comfort and fire safety for guests and staff at the hotel. The contract also includes ventilation for 47 luxury apartments within the same building.

The Hilton hotel forms the final phase in the £920 million, 42 acre, Liverpool One development by Grosvenor. A striking curved building by international architects Aedas, it echoes the elegant lines of Bath’s Royal Crescent. The hotel will overlook Chavasse Park, a new public open space. Lavish facilities including top class restaurants, bars, health club, meeting rooms and conference suites, will provide guests with a stay to remember.

Energy conservation is a key principle in the HVAC design. Heat recovery is therefore used on exhaust systems and rates of ventilation are closely related to occupancy and under the control of the building management system (BMS).

Heating and ventilation ductwork installation will take place during a 43 week fit out phase. Kier Build is responsible for design, construction and management of the services fit-out with Kier’s in-house M&E department. Hargreaves will supply and install backbone ductwork for air delivery and removal along with the smaller final connections.

For maximum flexibility and to give guests control, air input to bedrooms will be cooled or tempered by individual fan coil units regulated by room thermostat. This conditioned air will be delivered via a bulkhead plenum and grille into the room. Extract from bathroom pods will be via a single blade damper connection to 125mm galvanised ducts that feed into the main extract systems.

Plant rooms, some totally closed and others open to the sky, are located at mezzanine and roof level. Staff kitchens in the basement and the restaurant kitchen at ground floor level are ventilated by Hargreaves HFD kitchen extract fire duct. This is an insulated duct with access panels to permit thorough cleaning. Hargreaves standard specification stability, integrity and insulated HFD ducting is also used for smoke extract from the basement. HFD fire ducts are also used to supply the essential make-up air. The smoke extract ducts pass through the building to discharge safely at mezzanine plant room level.

The apartments are ventilated on a whole house basis with distribution via 204mm space saving plastic ductwork. These systems also have heat recovery, but are not connected to the hotel BMS. Continuous airflow is maintained at all times with facilities for occupiers to increase rates of air flow, heating and cooling as desired.


More Information

Phil Johnson, Tel. +44 (0)161 764 5082 Fax. +44 (0)161 762 2336
Email: pr@senior-hargreaves.co.uk Web: www.hargreaves-ductwork.co.uk
Senior Hargreaves, Lord Street, Bury, Lancashire BL9 0RG, UK


Release issued: September 3, 2008


Click image for full 300dpi view in a new window. Download Help


CGI of the The Hilton Hotel - the final phase in the £920 million Liverpool One development

Ductwork for air input and extract will ensure comfort and fire safety for guests and staff at the new Liverpool Hilton Hotel.


Close-up CGI of the The Hilton Hotel

Kitchens in the basement and the restaurant kitchen at ground floor level are ventilated by Hargreaves HFD kitchen extract fire duct.



Text Version Downloads
HVAC Building
Fire Safety
North West Region

Top of Page Return to Index | Back | Next  



© Ainsworth Maguire PR

T. +44 (0)161 447 8550  or  T. +44 (0)161 408 5608  E: pr@ainsmag.co.uk

www.ainsmag.co.uk  www.free-pr-advice.co.uk  www.freepradvice.wordpress.com


Public Relations Manchester PR - Public Relations Agency

Ainsworth Maguire

Home
Client News Rooms
Request a PR Quote
What is PR?
About the Partners
PR Services
About Online PR
PR Checklists & Advice
PR Blog
Company Brochures

Miscellaneous

Contact
Privacy Policy
Terms of Use
Our Copyright
Career at Ainsworth Maguire
Search Ainsworth Maguire
Resources & Links
Full Site Map

Client News Rooms

Crown Energy
Delavan Spray Technologies
Detectronic
Fueltek
Hanix Europe
Hawke International
Hyten / Bamtec
Rowe Hankins
Senior Hargreaves
Street Crane Company